Select Products
» ADC KRONE
» RF CABLE
» Jumper Cable, Connectors and Other Accessories
» LMR Cables
|
About Us
|
Products
|
Inquiry
|
Contact Us
»
RF CABLE
1/2" RF Cable
1/2" RF Superflexible
3-8 RF Cable
3-8 RF
Superflexible
7/8" RF Cable
7/8" RF Superflexible
1-1/4" RF Cable
1-1/4" RF Superflexible
1-5/8' RF Cable
»
RF Accessories
Earthing Kit
Weatherproofing Kit
Jumper Cables
Wall free Entry
Cable Clamps
SurgeArrestors
»
Leaky Coaxial Cable & Accessories
Leaky Cable
7/8" RF Cable
1-5/8" RF Cable
»
LMR CABLE
LMR 100
LMR 195
LMR 200
LMR 240
LMR 400
LMR 600
LMR 900
LMR 1200
Bundle Cable
»
Connectors
N M for 1/2"
N M for 1/2" S.F
DIN M for 1/2"
DIN M for 1/2" S.F
N M for 7/8"
DIN M for 7/8"
DIN M for 7/8" S.F
»
Antenna & Accessories
2 - 3 dBi Antenna
7 dBi Antenna
Grid Antenna
Power Splitter 2 Way
Power Splitter 3 Way
Power Splitter 4 Way
Directional Couplers
»
Solar Energy Systems
ADC KRONE
» integrated Protection Module
» Technical Specifications
Max. Operating voltage (a/b-e, a-b)
Vmax.e
180
V
Nominal DCspark-overvoltage
V
sdcn
180-300
V
Impulse spark-over voltage @ 1 kV/µs
(a/b-e)
Vº
< 900
V
Impulse life time (300* 10/1 OOOus, alternating polarity)
1
100
A
Nominal arrester surge current
(8/20 µs; a/b-e)
i
sN
5
kA
Nominal arrester alt. discharge current
(50hz, 1s; a/b-e)
i
daN
5
A(rms)
Fail safe response time @ 5 Arms
tf
< 5
S
Max. Operating current (a-a'/b-b') @ 25°C'
1
N
Max.
120
mA
Rated line resistance (a-a'/b-b') @ 145mA,25°C
R
6-25
Resistance balance
RPTC
< 0.5
Max. switching current of PTC @ Vmax=230Vms
ls max
3
A(rms)
Max. switching time PTC @ 1A (rms)
ts
2.5
S
Capacitance(1 MHz/1 Vms;a/b-e, a-b)
C
< 1.50
pF
Insulation resistance© 100V(a-b,a-e,b-e)
Riso
> 1000
MW
Operating temperature:
-20°...+60<C
Storage temperature:
-40°...+80°C
Electric characteristics:
1 ace. To ITU-T K. 12
Mechanical characteristics:
sinusoidal wave ace, To IEC 68-2-6
Climatic characteristics:
DIN IEC 68 part 2-2/3 (Thermal resistivity)
DIN IEC68part2-1(cold resistivity)
» Ordering Codes
Single Pair Protection Plug for LSA Seris2 MDF (1000 pairs Per vertical)
Protection Plug Single pair fitted with 3 pole failsafe
GD Tube two PTC's in series and disconnection
facilities for testing and isolation
(Each)
6905 2 330-00
Set of 10 with Earth Bar
(Each)
6905 1 330-00
Earth Bar 2/10
(Each)
6905 3 320-00
Single Pair Protection Plug Without Test Access (for LSA Plus Series 2 MDF)
Protection Plug Single pair fitted with 3 pole failsafe
GD Tube two PTC'sin series Without test access
(contact less)
(Each)
6905 2 604-01
Earth Bar 2/10
(Each)
6905 3 320-00